50ppm ENTRY LEVEL CALIBRATOR
Providing full functionality and 50ppm performance at entry level costs - increase you productivity today!

AC/AC Voltage to 1000V • AC/DC Current to 20A as standard • Resistance • Capacitance • Frequency • Complete with Thermocouple simulation option and 2 / 10 / 50 Clamp Coil Adapter (optional scope & AC Power option)
Use with ProCal software for automated calibration

Operations Guide
Download Brochure
Automated Calibration
Example Certificate
Virtual Front Panel
Back to Section Menu

View 2050 Add-on Options
VIEW

AVAILABLE OPTIONS
FOR 2050A
CALIBRATORS

 

 

 

 

Get 2050 operations Manual


*Password Protected

Contact Transmille for Access

 


*Please note: The manual and full colour brochures are large downloads (in excess of 2Mb)
To obtain a printed brochure please
click here


2050 :: ENTRY LEVEL MULTI PRODUCT CALIBRATOR
CLICK FOR PRINTABLE VERSION


Operations Guide VIEW 2050 FULL EXTENDED SPECIFICATIONS


1 YEAR BEST ACCURACY SPECIFICATIONS

FUNCTION


FUNCTION

MORE INFORMATION

Voltage DC


Range :
±0 to 1020V
Best Resolution : 0.1uV
Best 1 Year Accuracy : ±50ppm of setting


kV Amplifier available to extend
output to 10kV
Click here for details

Current DC


Range : ±0 to 20Amps
Best Resolution : 100pA
Best 1 Year Accuracy : ±0.05% of setting

Transconductance Amplifier
available to extend output to 100A
Click here for details

DC Resistance


Range : 0 to 1GOhm
Best 1 Year Accuracy : ±0.005% of setting

2 Wire Mode
Passive
decade resistors

Voltage AC


Range : 0 to 1020V
Best Resolution : 1uV
Frequency Range (Sine) : 40Hz to 10KHz
Best 1 Year Accuracy : ±0.07% of setting

kV Amplifier available to extend
output to 5kV
Click here for details

Current AC


Range : 0 to 20A
Best Resolution : 1nA
Frequency Range (Sine) : 40Hz to 500Hz
Best 1 Year Accuracy : ±0.1% of setting

Transconductance Amplifier
available to extend output to 70A
Click here for details

Capacitance


Range : 10nF & 1uF
Best 1 Year Accuracy : ±0.4% of setting

Passive decade capacitors for the best
compatibility with all bridges / meters

Thermocouple
Source


Range : -210°C to 1800°C
Best 1 Year Accuracy : ±0.04°C of setting

7 Types Built-In
Additional types available using
Virtual Front Panel Software
AC Power*
(Part of combined Scope/Power option)


Range : 0.3W to 1MW
Phase Adjustment : 0 ± 180° (0.1° steps)
Frequency Range : 40 to 400Hz
Best 1 Year Accuracy : ±0.11% of setting

Incorporates Dynamic Digital Phase Compenstation (DDPC) to dynamically
control the phase angle between
voltage and current waveforms.
Eliminate errors caused by
capacitive or inductive loads
Phase*
(Part of combined Scope/Power option


Range : 0 to 359.9°
Best Resolution : 0.1°
Best Life Accuracy : 0.2°

Oscilloscope*
Calibration
(Part of combined Scope/Power option


Amplitude Range : 2mV to 50V / Div
Best 1 Year Accuracy : ±0.01% of setting

Timebase Range : 5s to 2ns / Div
Best 1 Year Accuracy : ±5ppm

Levelled Sweep Range : 5MHz to 250MHz
Best 1 Year Accuracy : 1db

50kHz Reference
Best 1 Year Accuracy (Frequency) : 30ppm
Best 1 Year Accuracy (Level) : ±0.5%

 
GENERAL SPECIFICATIONS
   

Warm Up Time

Double the time since last used up to 20 minutes maximum

Standard Interface

RS232

Optional Interface

GPIB / USB

Temperature Performance

Storage : -5°C to +60°C
Operation : 0°C to +50°C
Calibration 17°C to 30 °C

Temperature Coefficient

Specifications apply between 17°C and 30 °C
Outside this range an allowance of 0.18 x 1 year specification per °C should be added

Relative Humidity

Operation <80% to 30°C, <70% to 40°C , <40% to 50°C
Storage : <95% (non-condensing)

Altitude

Operation : 3000m (10,00ft) Maximum
Transit : 12000m (40,000ft) Maximum

EMC & Safety

The calibrator line inlet plug must be earthed
See D.O.C. for full details

Low Analogue Isolation

100V

Line Power

Line voltage selectable : 110V / 230V
Line frequency : 50Hz to 60Hz
Line voltage variation : -6% +10%

Power Consumption

28 Watts (Standby)

Dimensions

Calibrator Only : 43cm x 46cm x 19mm
Calibrator in shipping box : 58cm x 56cm x 37cm
Calibrator in soft carry case : 49cm x 50cm x 19cm
Calibrator in hard transit case : 55cm x 56cm x 26cm

Weight

Calibrator Only : 12.5kg
Calibrator in shipping box : 15kg
Calibrator in soft carry case : 13.5
Calibrator in hard transit case : 22kg

 
 

* Denotes option
Due to continuous development specifications may be subject to change