2080 Electrical Test Box

< Back < Home < Site Map  
 Multi Product Calibrators ▪ Electrical Test Calibrators ▪ Hand Held / Bench Calibrators ▪ Calibration Service ▪ Software ▪ Online Certificates
2080

 


Transmille Ltd.
Unit 4,
Select Business Centre
Lodge Road, Staplehurst
Kent TN12 0QW
United Kingdom

Telephone
+44(0)1580 890700

Facsimile
+44(0)1580 890711

Email
sales@transmille.com


0324

Download Acrobat Reader
All data in
Adobe Acrobat®

The 2080 is housed in a robust plastic case with integral handle - ideal for on or off site use.
SPECIFICATIONS

LOOP Testers
Supply Loop • Supply Loop + 1Ohm : 5%

Insulation Testers
1MOhms : 9.9MOhms : 99MOhms : 1% Max. Test Voltage 1.2kV

Continuity Testers
0.5Ohms : 2Ohms : 10Ohms : 1Ohms± 20mOhms
Max. Current 300mA

RCD Testers
10mA (Nominal) @150ms
30mA (Nominal) @ 150ms
150mA (Nominal) @30ms

 General Information

Tests..
• Insulation & Continuity Testers
• RCD Testers
• LOOP Testers
• Combined Installation Testers


A fully featured test box for use in testing electrician’s equipment, the 2080 provides a fast solution for the requirement of regular verification of electrical test equipment.

2080 User Guide




View
the 2080
user guide here

Designed with low cost and portability in mind, the use of the 2080 provides on or off site verification of RCD Testers, LOOP Testers, Continuity and Insulation Testers.

The 2080 is simple to use and provides the following functionality:

Checking of Insulation Testers

• 3 high value resistors (1M Ohms, 9.9M Ohms & 99M Ohms) for testing the resistance measurement function.
• LED indication of test voltage at 100V • 250V • 500V • 1000V
• 3 low value resistors ( 0.5 Ohms, 2 Ohms & 10 Ohms) for testing the continuity function.
• AC line voltage output for testing voltage measurement

 

Checking of RCD Testers

• Dedicated 13A socket provides functional check of RCD tester operation
• 3 selectable ranges : 10mA@150ms • 30mA@150ms • 150mA@30ms
• Indicators for ReadyTrippedOvercurrent

 

Checking of LOOP Testers

A functional check of LOOP Testers, allowing direct measurement of supplied loop impedance and supplied loop impedance + 1 Ohms via a dedicated 13A socket.

 

Wiring Check

When connected, the 2080 checkbox will indicate voltage between the following wires *
P-E (Phase to Earth) • P-N (Phase to Neutral) • N-E (Neutral to Earth)
* Does not detect Neutral to Earth reversal

 

Certification

Calibration Certificates traceable to UK National Standards or UKAS are available.

 