SPECIFICATIONS
Continuity
Resistance
8 Values
0.2 Ohms, 0.5 Ohms, 1.0
Ohm, 5.0 Ohms, 10 Ohms, 100 Ohms, 1kOhm, 10kOhms
Accuracy
0.5% ± 40mohms
Max Current / power
300mA or 1W
Continuity
Current (into 1 ohm)
0 to 320mA
0.1mA resolution. 1.5%
± 6 counts
Insulation
Testing
8 Values
50kOhms, 100kOhms, 250kOhms,
500kOhms, 1MOhm, 10Mohms, 100MOhms, 1GOhm
Accuracy
0.5% up to 1MOhm. 2%,
10MOhm & 100MOhm 5% 1GOhm
Max Current / power
1.1kV or 1W
Insulation
Test Voltage Measurement
Ranges
50V, 100V, 250V, 500V,
1000V 0.1V Resolution
Nominal current 1mA
Current Measurement
1% ± 8 counts
AC
Voltage
230V Nominal 0.5%
± 1 count
RCD
Testing
Time 20ms
to 2s
Accuracy 0.7ms
Current 3mA
or 1A
Resolution
0.01mA to 200mA, 0.1mA
to 1A
Current Accuracy
<190 ms 5% ±
20 counts
>190ms 1.2% ± 6 counts
Loop
Testing
Resistance
50 mOhms, 150 mOhms, 500 mOhms, 1 Ohm, 5 Ohms, 10 Ohms,
100 Ohms, 1kOhms
Resolution
0 to 100Ohm ranges : 1mOhm 1kOhm range : 100mOhms
Accuracy
0.5% ± 4mohms
Auto
Loop
Maximum correction
2 Ohms
Resolution
100 uOhms
Accuracy
±18 mOhms
Measurement current
4A
|