MODEL 3200 OPTIONS & ACCESSORIES ::

SELECT >>>


OPTION FLASH :: PAT FLASH TEST ADAPTER (CLASS 1 & 2)

  The flash test adapter option provides a fast, safe and easy method for measuring PAT flash voltage and current at CLASS 1 and CLASS 2 settings. The design of the flash test adapter allows direct connection of the PAT flash probe, holding it down safely on the voltage input connector of the adapter.      
     

OPTION HIRES :: HIGH RESISTANCE MULTIPLIER ADAPTER (TO 15kV)

  The high resistance multiplier adapter for the 3200 provides a low cost solution for the resistance calibration of some makes of high voltage (above 1kV) insulation testers avoiding the problem of obtaining high value, high resistance resistors.

The adapter both increases the test voltage at which the calibration can be performed*, and also increases the resistance range of the 3200 by a factor of 10. This allows the standard 3200 to be used for resistance calibration of testers up to 15kV at up to 200 GOhms. With the 10 GOhms option fitted to the 3200 values of up to 1 TOhm can be simulated.

* Note : Does not measurement test voltage
     
     

OPTION 2102 :: HIPOT / BREAKDOWN ADAPTER

  The hipot / breakdown tester adapter offers a unique solution to the safe, fast calibration of both voltage output and leakage current measurements on hipot and breakdown testers. Desinged to sit flat on the bench the high voltage probes, with a switch in the handle, often used with breakdown testers can be safely pressed down on the terminals.

The breakdown adapter provides 3kV & 12kV voltage measurement ranges for both AC and DC. LEDs indicate which terminal should be used.

To calibrate the output/leakage current display of the hipot / breakdown tester the adapter provides 9 high power resistors to provide current loads of up to 20mA @ 1000V - a function not available on other calibrators.
     
     

OPTION HIACC :: HIGH ACCURACY RESISTANCE OPTION

  Higher Accuracy - approximately 3 times better for the insulation resistance and continuity resistance 
(NOT RETRO-FITTABLE)
     
     

OPTION 10G :: 10 GOHM RESISTANCE OPTION

  Extends the resistance range for the standard 2G Ohms to 10G Ohms to cover calibration of insulation testers with higher ranges (RETRO-FITTABLE)      
     

 OPTION AUTOLOOP :: AUTO LOOP MEASUREMENT OPTION

  The auto loop impedance measurement and correction function provides an easy way to measure the loop impedance and add this to the calibrated resistance values stored in the 3200.

At the press of a button, the 3200 measures the loop impedance of the supply it is connected to and adds this measured value to the calibrated value displayed when a loop resistance is selected. For example a measured loop impedance of 0.15 Ohms will result in a corrected value of the
[calibrated value] + [0.15 Ohms].

This provides an accurate and repeatable method for calibrating loop testers even when calibrating on-site.
     
     

OPTION EXTRES :: EXTERNAL RESISTOR OPTION

  Add an additional two custom resistors to the available LOOP and PAT Earth Bond Resistance values via 4mm terminal input on the rear of the 3200 (RETRO-FITTABLE)      
     