 FEATURES


COMPLETE STAND-ALONE BATTERY OPERATION
DUAL VOLTAGE 100V / 240V
BUILT-IN QWERTY MEMBRANE KEYBOARD
SUPPORTS DETAILED APPLIANCE RECORD KEEPING
IEC / EXTENSION LEAD CHECK FUNCTION
SELF CHECK FUNCTION
FUSE CONTINUITY TEST
EARTH BOND CURRENT @ 25A/10A/100mA
INSULATION RESISTANCE @ 500V
LEAKAGE CURRENT @ 230V
FUSE TEST • VISUAL YES / NO
SUPPLIED WITH EXTERNAL FAST CHARGER
DATA DOWNLOAD READY
OPTIONAL BARCODE SCANNER
(OPTIONAL PC SOFTWARE & DATA CABLE AVAILABLE)

5080 / 6080 - Introduction :
PowerPoint® Presentation
(5MB)

(RIGHT CLICK AND CHOOSE 'SAVE TARGET AS...' TO DOWNLOAD)

6080PLUS :: EXPANDED FUNCTION PAT

Get your safety testing off to a rapid start with the new concept in portable appliance testing. Transmille has redefined PAT operation for the ultimate in speed and simplicity of use.

Pressing the CLASS 1 button sets the 6080PLUS to automatically sequence through a visual check, fuse check, earth bond resistance, insulation resistance and leakage current test for each appliance.
The CLASS 2 button performs the same sequence without the earth bond test.

Pass or fail is clearly shown using bright red/green LED bar displays for each test - this makes reading and understanding the results easy for all levels of users. Pass / fail limits scale automatically with the earth bond current used, the lead length and the test type. Readings are also displayed on a digital LCD.

6080PLUS :: ADDITIONAL FUNCTIONALITY

Expanding on the strengths of the 5080 PAT, the 6080
PLUS adds dual voltage capabilities for complete 110V / 240V compatibility with separate outputs for each voltage.

The IEC / extension lead check function leads to be verified independently. The self check function allows the 6080PLUS to be verified using its own built in test facility - simply connect to the self check outputs to confirm correct PAT operation

Fuse GO / NO GO function allows fuse continuity to be checked with LED indication of result.

The 6080PLUS includes larger battery capacity to provide longer test times between charging.

6080PLUS :: APPLIANCE/ASSET MANAGEMENT

For complete record keeping, the
6080PLUS incorporates the ability to store comprehensive appliance details including serial number, appliance/asset number, site, location and retest interval using its built-in keyboard. This data is stored in memory until downloaded to the PC for use in professionally formatted reports and testing certificates.

Unique to the 6080PLUS, appliances can be automatically uploaded to the 6080PLUS using the optional software to remove the need for re-entering details of 'known' appliances.

PRODRS :: PC CONNECTION FOR DATA DOWNLOAD/UPLOAD & REPORTING

All tests performed are stored in the 6080PLUS memory together with a unique test number and date.

Downloading the results from the 6080PLUS is a snap using the PC connection kit (option). One click is all that is required to fetch the data and display a report of all your work done.



Easy function selection - Download, Reports, Edit Appliances, Upload Appliance or Print Labels


'1 CLICK' Download - Simply click Download Data on PC.
Press any button on the PAT to begin download




Easy Report Printing - enter customer/location details
and tested by name then click PRINT

 SPECIFICATIONS

Earth Bond Resistance measurement
0 to 10 Ohms @ 100mA / 10A / 25A Nominal (5s into S/C) : 3% ± 4 Digits

Insulation Resistance Measurement 0.1M Ohms to 100M Ohms @ 500V Accuracy 3% ± 4 Digits

Leakage Current Measurement
0.1mA to 15mA @ 240V / 50Hz Accuracy 3% ± 0.2mA

Fuse Test
Pass / Fail

Fuse Continuity Check
Pass / Fail LED indication

Lead Length Correction
Slider control 1 to 5m

Lead Check
Separate IEC connection and independent test button

Self Check
Earth Bond Resistance @ 0.4 Ohms
Insulation Resistance @ 7MOhms
Leakage Current @ 1mA

Battery Life
Typical 700 Tests
Per recharge

Mains Operation
Continuous operation with
supplied charger

Recharge time
6 hours

Internal Memory Capacity
1000 Tests
(unlimited with PC based storage)


Dimensions (mm)
390 x 280 x 110

Weight
3.9kg

6080PLUS :: OPTIONAL ACCESSORIES

BARCODE SCANNER

Use the optional barcode scanner to automatically scan asset/appliance labels (requires use of barcoded asset/appliance labels)


BARCODED APPLIANCE LABELS


Use with the optional barcode scanner to allow easy data input and appliance recognition (in conjunction with optional PRODRS software)


Due to continuous development specifications are subject to change.

 

Back to top