3000 Series Precision References
Transmille present a range of precision references to compliment the Transmille product range
3000CS : Precision Current Shunt Array
A dedicated precision current shunt array with a set of four shunts with built-in temperature measurement provided via PRT output
3000RS : Precision Resistance Standard
A dedicated precision resistance standard suitable for use as a working standard or transfer standard
3000ZR : Precision Voltage Reference
An integrated 1.018V and 10V reference standard using a multi cell zener references with internal rechargeable battery backup
|
8000 Series Precision Multimeter

PRECISION 8.5 / 7.5 DIGIT MULTIMETERS
Provides outstanding accuracy and linearity measurement performance together with ease of use. Incorporating the latest in precision foil resistors , with temperature co-effiecients less than 1ppm / °C
Programmable Terminal Switching
Allows remote control of front/rear input switching directly from the PC or front panel menu for switching between a reference standard and unknown (UUT)
Intelligent Reference Ratio Function
A unique operating mode allows a known reference standard to be connected to the rear terminals, the unknown to the front terminals for ratio measurement. The 8000 Series can them automatically switch between the standards, displaying the value of the unknown as directly compared against the entered value of the known.
Temperature Measurement (8081)
Precision temperature measurement using PRT probes. 8081 includes advanced modes for co-efficient storage of SPRT probes.
Pressure Measurement (8081)
The Transmille range of pressure modules can be used with the 8000 Series using the built-in adapter interface for direct pressure display.
Low Current Measurement (0.1pA to 10uA)
8081 DC Current ranges down to 10nA with a resolution of 0.1pA using a dedicated screened BNC input. This input offers a ‘virtual’ ground approaching zero input impedance providing electrometer performance in an integrated DMM package.
High Value Resistance Measurement
8081 resistance measurement up to 1 TOhm can be achieved using the dedicated low current screened BNC input (essential for low noise / high value resistance measurement). A high voltage (200V) source combined with a sub pA input provides a high performance resistance measurement system offering electrometer performance in an integrated DMM package.
|
ProCal
From stand-alone setups to fully networked configurations
From simple data entry through to fully automated calibration. Create procedures from scratch in minutes using the built in Procedure Wizard
- Complies with UKAS / ISO quality requirements
- Prints calibration certificates and labels
- Fast procedure writing - procedure wizard feature
- Technical help file system
- GPIB / RS232 instrument control for a wide range of manufacturers
- Calibration priority management
- Text & Picture calibration prompts
- Multi-Language support
|